- New
Replacement Cartridge for Coldstream Coldstream Undercounter & Coldstream Countertop (Pressure On, Not Suitable for Gravity Systems) / Fits Doulton Inox HCS Sink Filter.
The advantages of the Coldstream Max:
Sustainability:
We recommend replacing it every 6 months. Activated carbon, once the device is put into operation, has an effective duration of 6 months.
Particulate matter
Up to 99.9% reduction in Class 1 particles, including microplastics.
Bacteria and cysts
Up to 99.9999% reduction in tested bacteria (Klebsiella terrigena) and 99.9% in cysts (Cryptosporidium spp.), based on independent laboratory tests at 3,000 and 4,500 liters.
Chemicals
Very high reduction of free chlorine and chloramine, as well as a wide range of volatile organic compounds (VOCs) and chlorination by-products (THMs). Most of the VOCs tested are reduced to more than 99%, with a few specific compounds partially reduced
Heavy metals
Significant reduction of a wide range of heavy metals (aluminum, antimony, barium, cadmium, chromium, copper, lead, etc.), with reduction levels often exceeding 90% and up to more than 99% depending on the metals and volumes tested.
Viruses
Up to 99.99% reduction in rotavirus, tested to NSF/ANSI P231 (at 3,000 and 4,500 liters)
Pesticides and herbicides
Very high reduction (typically >97% and up to 99.9%) on most pesticides and herbicides tested, including DDT and many other modern pesticides.
Medications
Very high reduction, often greater than 99–99.9%, on a wide range of pharmaceutical residues and hormones (BPA, ibuprofen, naproxen, steroid hormones, etc.).
Note on nitrates and fluoride
Laboratory tests on some configurations of CTO MAX cartridges (including CF504W/CF1075W) show a strong reduction in nitrates and nitrites up to several thousand liters. However, this cartridge is not presented as a specific treatment for nitrates or fluoride.
*For more information on arsenic, VOCs, and cysts, see the Performance Data Sheet.
Coldstream Max filters have undergone rigorous testing programs via an independent testing laboratory and independent audits without prior notice to ensure manufacturing compliance.
They have been successfully tested according to the following standards and methods:
– Reduction of viruses (rotavirus) >99.99% at 3,000 and 4,500 L
– Reduction of bacteria (Klebsiella terrigena) >99.9999%
– Cyst reduction (Cryptosporidium) >99.9%
? Recommended for maximum protection, even when the origin of the water is uncertain (disinfected cistern water, wells, etc.).